Newborn Care

  • 0 out of 5

    Baby Incubator Chello S1000

    Product Features

    Function features:
    – Temperature displayed by LED
    – >37°C temperature setting
    – A keypad lock to prevent inadvertent changes in setting
    – A second thermal cut-out function for extra safety
    – Natural airway humidity
    – Heating power display
    – Adjustable infant bed inclination angle
    – Alarm functions: power failure, over temperature, temperature
    deviation, temperature sensor failure, fan failure

    Main characteristic:
    – Water trough for pulling and pushing, conveniently adding water and washing
    – Fan designed for low noise and long life span
    – Temperature deviation and over temperature can be amended directly using front panel
    – Equipped with silence/reset button alarm
    – Six operation windows, the two side access  operating

  • 0 out of 5

    Baby Incubator Chello S2000

    Product Features

    Function features:
    – Microprocessor based servo controlled temperature system
    – Integral timer to record therapy time
    – Control Mode for Air temperature and skin temperature
    – Over 37°C temperature setting
    – Continuously adjustable humidity
    – Come with oxygen port and Rs323 connector
    – Adjustable Infant bed inclination angle
    – A Keypad lock to prevent inadvertent changes in setting
    – Alarm Functions: Power failure, Over temperature, Temperature deviation, Fan failure, Temperature sensor failure
    – Equipped with skin temperature sensor fall which protect unit against over temperature – Air temperature, skin temperature, humidity, timer and heat power displayed by LED separately

    Main Characteristic:
    – Water trough for pulling and pushing, conveniently adding water and washing
    – Fan designed for low noise and long life span
    – Temperature deviation and over temperature can be amended directly using front panel
    – Equipped second thermal cut-out function for extrasafety feature
    – Adjustable infant bed inclination angle
    – Six operation windows, the two side access operating windows can be swivelled
    – Come with 4 drawers for storage

  • 0 out of 5

    Baby Incubator Chello S3000

    Product Features

    Function features:
    – Microprocessor based servo controlled temperature system
    – 8′ colour touch screen with skin temperature graph trends
    – Control modes for air and baby skin mode
    – Humidity control and oxygen concentration control system
    – SPO2 monitoring system
    – Self-test function, various failure alarms delivered by audio and visual
    – >37° temperature set function
    – Embedded integrated sensor module
    – Triple protection for over temperature with separate cut off device, more safety system
    – Set temperature, air temperature, baby skin temperature, humidity, oxygen concentration, SPO2 and heating power are displayed separately by LCD
    – The inclination of infant bed is adjustable
    – Double wall hood, 4 operating windows and 2 iris ports
    – Independent locking device for front door
    – X-ray cassette tray
    – RS232 connector, Oxygen inlet, 1 tray

  • 0 out of 5

    Infant Radiant Warmer Infarmed 100C

    Product Features

    – Microprocessor based servo controller temperature system
    – Three modes microprocessor-controller unit : pre-warm, manual and automatic
    – Alarm functions or safety which include: power failure, temperature deviation, temperature probe failure, over temperature
    – APGAR timer o record therrrapy time
    – Heater head can be adjusted ± 90° horizontally
    – Adjustable tilt angle infant bed
    – Transparent protector folded
    – Convenient X-ray cassete, board, board under infant bed
    – Alarms are audible and visual
    – A second thermal cut-out function or xtra safety
    – Skin temperature sensor failure to protect avoiding over temperature
    – With RS232 connector

  • 0 out of 5

    Infant Radiant Warmer Infarmed 100UP

    Spesification
    • The Scoop Stretcher can be divided into le and rig t halves by the clutches in both ends, side lock buton is easy open.
    • The scoop stretcher has extra low profile for sliding the stretcher easily beneath the pae t to minimize the risk of further injury.
    • Adjustable length according to pae t’s height, easy to lock & unlock, and foldable.
    • The scoop stretcher is made of polyethylene ,allow X-ray
    • Can be used together with head immobilize
    • Mainly used for ambulance, hospitals, emergency centers


  • 0 out of 5

    Neonate LED Phototheraphy Ecoblu 500

    Product Features
    – Five blue light tubes as phototherapy radiantsource
    – Equal light distribution
    – High intensity
    – Adjustable height and angle of the head
    – Timer for total using time and individual treatmenttime
    – Steel support pole
    – Lockable wheels

    Technical Data
    Power supply : AC 110/220V 60/50Hz
    Power input : 120VA
    Wavelength (blue light) : 400nm~550nm
    Total irradiance for bilirubin : 1250µ W/cm
    Height adjust range : : 1350 ~ 1650mm
    Pitching angle of phototherapy head : ±90°
    Time accuracy : 1min/12h
    Integral time range :  0h~9999h 59min

    Operating condition
    Temperature : 18°~30°C
    Relative humidity : 30%~75% RH
    Atmospheric pressure : 700 hPa~1060 hPa

    Transport and storage
    Ambient temperature : -10°C~+55°C
    Relative humidity : ≤80%
    Atmospheric pressure :  500 hPa~1060 hPa

  • 0 out of 5

    Neonate LED Phototheraphy Ecoblu D1000

    Product Features
    – LED bulbs as phototherapy radiant source
    – Button control switch
    – Equal light distribution, high intensity
    – Quite, two cooling fan, long life span
    – Timer for total using time and each treatment time
    – Count down timer
    – Instal under infant bed, use for neonate bilirubinphototherapy treatment
    – Irradiance intensity is automatic adjustment, to prevent the bed’s temperature higher
    – Adopts aluminum PCB to help element head dissipation

    Technical Data
    Power supply : AC 220/50Hz
    Adapter output : DC 12V 1A
    LED light box power input : 8VA x 2
    Wavelength (blue light) : 420nm~490nm W/cm2
    Total irradiance for bilirubin : 1200µ W/cm
    Noise level : ≤55dB (A)
    Adapter output
    LED light box power input
    Wavelength (blue light)
    Total irradiance for bilirubin
    Noise level

    Operating condition
    Temperature : 18°C~+30°C
    Relative humidity : 30%~75% RH
    Atmospheric pressure : 700 hPa~1060 hPa

    Transport and storage
    Ambient temperature :-10°C~+55°C
    Relative humidity : ≤95%
    Atmospheric pressure : 500 hPa~1060 hPa

  • 0 out of 5

    Neonate LED Phototheraphy Ecoblu D300

    Product Features
    – LED bulbs as phototherapy radiant source
    – Button control switch
    – Equal light distribution, high intensity
    – Quite fan, long life span
    – Timer for total using time and each treatment time
    – Count down timer
    – Usually used on top of infant incubator for neonate bilirubin phototherapy treatment

    Technical Data
    Power supply : AC 110V~220V 50/60Hz
    Power input : 45VA
    Radiant wavelength :≥425nm~475nm
    Total irradiance for bilirubin : 2800µ W/cm
    Height adjust range : 1200 ~ 1600mm
    Adjust angle of phototheraphy box : 0°~90°
    Time accuracy :2h±1min
    Integral time range : 0h~9999.9h

    Operating condition
    Temperature : 18°C~30°C
    Relative humidity : 10%~85% RH
    Atmospheric pressure : 700 hPa~1060 hPa

    Transport and storage
    Ambient temperature :-10°C~+55°C
    Relative humidity : ≤95%
    Atmospheric pressure : 500 hPa~1060 hPa

  • 0 out of 5

    Neonate LED Phototheraphy Ecoblu D500

    Product Features
    – LED bulbs as phototherapy radiant source
    – Button control switch
    – Equal light distribution, high intensity
    – Quite fan, no noise of fan
    – The angle of head and height are adjustable
    – Steel support pole, lockable wheels with four castors
    – Separate record for therapy and integral time
    – Long life spam

    Technical Data
    Power supply : AC 110/240V, 50/60Hz
    Power input : 45VA
    Radiant wavelength : 420nm~490nm W/cm
    Total irradiance for bilirubin : 2800µ W/cm
    Height adjust range : 1300 ~ 1600mm
    Adjust angle of phototheraphy box : ±90°
    Time accuracy : 1min/12h
    Integral time range : 0h~9999h

    Operating condition
    Temperature : 18°C~+30°C
    Relative humidity : 10%~85% RH
    Atmospheric pressure : 700 hPa~1060 hPa

    Transport and storage
    Ambient temperature : -10°C~+55°C
    Relative humidity : ≤95%
    Atmospheric pressure : 500 hPa~1060 hPa